H07Z1-R Power Cable for Public Buildings

Maximum temperature range during operation : 70°C
Maximum short circuit temperature (5 Seconds) : 160°C
Minimum bending radius :
OD<8mm : 4 × Overall Diameter
8mm≤OD≤12mm : 5 × Overall Diameter
OD>12mm : 6 × Overall Diameter


Product Detail

Product Tags

CABLE CONSTRUCTION

Conductor : Copper conductor according to BS EN 60228 class 1/2/5.

H07Z1-R : 1.5-630mm2 Class 2 stranded copper conductor to BS EN 60228.

Insulation : Thermoplastic compound of type TI 7 to EN 50363-7.

Insulation Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

Type and Material: H07Z1-R is a single-core, low-smoke, halogen-free insulated stranded rigid wire, meaning that it is low-smoke and halogen-free, which reduces the production of toxic fumes in case of fire and is suitable for locations with high environmental and personnel safety requirements.
Applicable Voltage:This wire is suitable for use in circuits with AC voltages up to 1000V or DC voltages up to 750V, making it suitable for internal wiring with high voltage requirements.

Working temperature: The maximum working temperature is 90°C, indicating that it can withstand higher temperature environments and is suitable for installation in pipelines or inside electrical appliances.

Insulation material: Halogen-free flame retardant material is used, which improves the cable’s fire resistance and environmental friendliness.

COLOUR CODE

Black, Blue, Brown, Grey, Orange, Pink, Red, Turquoise, Violet, White, Green and Yellow.

PHYSICAL AND THERMAL PROPERTIES

Maximum temperature range during operation : 70°C
Maximum short circuit temperature (5 Seconds) : 160°C
Minimum bending radius :
OD<8mm : 4 × Overall Diameter
8mm≤OD≤12mm : 5 × Overall Diameter
OD>12mm : 6 × Overall Diameter

 

FEATURES

Halogen-free flame retardant: In case of fire, it will not release a lot of harmful gases, which is in line with environmental protection and safety standards.

Low Smoke: Produces less smoke when burning, which facilitates clear vision and evacuation of people in case of fire.

Internal wiring: Designed for wiring inside equipment or specific electrical installations, emphasizing its use in restricted spaces or specialized equipment.

High Temperature Resistance: Can work stably at higher temperatures, ensuring reliability for long-term use.

APPLICATION

Telecommunications facilities: Due to its halogen-free and flame-retardant properties, H07Z1-R is commonly used for the internal wiring of telecommunications installations and modules.

Public Buildings: Used for internal electrical systems in public buildings, such as hospitals, schools, and office buildings, where the safety of personnel and the reduction of fire risk need to be considered.

Inside electrical equipment: For electrical equipment that requires wires to operate safely in a limited space, such as switches, control panels, etc.

Protective laying: can be used inside or around lamps to ensure safe wiring in lighting equipment.

To summarize, H07Z1-R power cords are mainly used in electrical installation and internal wiring scenarios of equipment that require strict safety standards due to their safe, environmentally friendly and high temperature resistant characteristics.

 

CONSTRUCTION PARAMETERS

Conductor

FTX100 07Z1-U/R/K

No. of Cores × Cross-sectional Area

Conductor Class

Nominal Insulation Thickness

Min. Overall Diameter

Max. Overall Diameter

Approx. Weight

No.×mm²

mm

mm

mm

kg/km

1×1.5

1

0.7

2.6

3.2

22

1×2.5

1

0.8

3.2

3.9

35

1×4

1

0.8

3.6

4.4

52

1×6

1

0.8

4.1

5

73

1×10

1

1

5.3

6.4

122

1×1.5

2

0.7

2.7

3.3

24

1×2.5

2

0.8

3.3

4

37

1×4

2

0.8

3.8

4.6

54

1×6

2

0.8

4.3

5.2

76

1×10

2

1

5.6

6.7

127

1×16

2

1

6.4

7.8

191

1×25

2

1.2

8.1

9.7

301

1×35

2

1.2

9

10.9

405

1×50

2

1.4

10.6

12.8

550

1×70

2

1.4

12.1

14.6

774

1×95

2

1.6

14.1

17.1

1069

1×120

2

1.6

15.6

18.8

1333

1×150

2

1.8

17.3

20.9

1640

1×185

2

2

19.3

23.3

2055

1×240

2

2.2

22

26.6

2690

1×300

2

2.4

24.5

29.6

3364

1×400

2

2.6

27.5

33.2

4252

1×500

2

2.8

30.5

36.9

5343

1×630

2

2.8

34

41.1

6868

1×1.5

5

0.7

2.8

3.4

23

1×2.5

5

0.8

3.4

4.1

37

1×4

5

0.8

3.9

4.8

54

1×6

5

0.8

4.4

5.3

76

1×10

5

1

5.7

6.8

128

1×16

5

1

6.7

8.1

191

1×25

5

1.2

8.4

10.2

297

1×35

5

1.2

9.7

11.7

403

1×50

5

1.4

11.5

13.9

577

1×70

5

1.4

13.2

16

803

1×95

5

1.6

15.1

18.2

1066

1×120

5

1.6

16.7

20.2

1332

1×150

5

1.8

18.6

22.5

1660

1×185

5

2

20.6

24.9

2030

1×240

5

2.2

23.5

28.4

2659

ELECTRICAL PROPERTIES

Conductor operating temperature : 70°C

Ambient temperature : 30°C

Current-Carrying Capacities (Amp) according to BS 7671:2008 table 4D1A

Conductor cross-sectional area

Ref. Method A (enclosed in conduit in thermally insulating wall etc.)

Ref. Method B (enclosed in conduit on a wall or in trunking etc.)

Ref. Method C (clipped direct)

Ref. Method F (in free air or on a perforated cable tray horizontal or vertical)

Touching

Spaced by one diameter

2 cables, single-phase a.c. or d.c.

3 or 4 cables, three-phase a.c.

2 cables, single-phase a.c. or d.c

3 or 4 cables, three-phase a.c.

2 cables, single-phase a.c. or d.c. flat and touching

3 or 4 cables, three-phase a.c. flat and touching or trefoil

2 cables, single-phase a.c. or d.c. flat

3 cables, three-phase a.c. flat

3 cables, three-phase a.c. trefoil

2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat

Horizontal

Vertical

1

2

3

4

5

6

7

8

9

10

11

12

mm2

A

A

A

A

A

A

A

A

A

A

A

1.5

14.5

13.5

17.5

15.5

20

18

-

-

-

-

-

2.5

20

18

24

21

27

25

-

-

-

-

-

4

26

24

32

28

37

33

-

-

-

-

-

6

34

31

41

36

47

43

-

-

-

-

-

10

46

42

57

50

65

59

-

-

-

-

-

16

61

56

76

68

87

79

-

-

-

-

-

25

80

73

101

89

114

104

131

114

110

146

130

35

99

89

125

110

141

129

162

143

137

181

162

50

119

108

151

134

182

167

196

174

167

219

197

70

151

136

192

171

234

214

251

225

216

281

254

95

182

164

232

207

284

261

304

275

264

341

311

120

210

188

269

239

330

303

352

321

308

396

362

150

240

216

300

262

381

349

406

372

356

456

419

185

273

245

341

296

436

400

463

427

409

521

480

240

321

286

400

346

515

472

546

507

485

615

569

300

367

328

458

394

594

545

629

587

561

709

659

400

-

-

546

467

694

634

754

689

656

852

795

500

-

-

626

533

792

723

868

789

749

982

920

630

-

-

720

611

904

826

1005

905

855

1138

1070

Voltage Drop (Per Amp Per Meter) according to BS 7671:2008 table 4D1B

Conductor cross-sectional area

2 cables d.c.

2 cables, single-phase a.c.

3 or 4 cables, three-phase a.c.

Ref. Methods A&B (enclosed in conduit or trunking)

Ref. Methods C & F(clipped direct,聽on trays or in free air)

Ref. Methods A & B (enclosed in conduit or trunking)

Ref. Methods C & F (clipped direct, on trays or in free air)

Cables touching, Trefoil

Cables touching, flat

Cables spaced*, flat

Cables touching

Cables spaced*

1

2

3

4

5

6

7

8

9

mm2

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

1.5

29

29

29

29

25

25

25

25

2.5

18

18

18

18

15

15

15

15

4

11

11

11

11

9.5

9.5

9,5

9.5

6

7.3

7.3

7.3

7.3

6.4

6.4

6.4

6.4

10

4.4

4.4

4.4

4.4

3.8

3.8

3.8

3.8

16

2.8

2.8

2.8

2.8

2.4

2.4

2.4

2.4

r

x

z

r

x

z

r

x

z

r

x

z

r

x

z

r

x

z

r

x

z

25

1.75

1.8

0.33

1.8

1.75

0.2

1.75

1.75

0.29

1.8

1.5

0.29

1.55

1.5

0.175

1.5

1.5

0.25

1.55

1.5

0.32

1.55

35

1.25

1.3

0.31

1.3

1.25

0.195

1.25

1.25

0.28

1.3

1.1

0.27

1.1

1.1

0.17

1.1

1.1

0.24

1.1

1.1

0.32

1.15

50

0.93

0.95

0.3

1

0.93

0.19

0.95

0.93

0.28

0.97

0.81

0.26

0.85

0.8

0.165

0.82

0.8

0.24

0.84

0.8

0.32

0.86

70

0.63

0.65

0.29

0.72

0.63

0.185

0.66

0.63

0.27

0.69

0.56

0.25

0.61

0.55

0.16

0.57

0.55

0.24

0.6

0.55

0.31

0.63

95

0.46

0.49

0.28

0.56

0.47

0.18

0.5

0.47

0.27

0.54

0.42

0.24

0.48

0.41

0.155

0.43

0.41

0.23

0.47

0.4

0.31

0.51

120

0.36

0.39

0.27

0.47

0.37

0.175

0.41

0.37

0.26

0.45

0.33

0.23

0.41

0.32

0.15

0.36

0.32

0.23

0.4

0.32

0.3

0.44

150

0.29

0.31

0.27

0.41

0.3

0.175

0.34

0.29

0.26

0.39

0.27

0.23

0.36

0.26

0.15

0.3

0.26

0.23

0.34

0.26

0.3

0.4

185

0.23

0.25

0.27

0.37

0.24

0.17

0.29

0.24

0.26

0.35

0.22

0.23

0.32

0.21

0.145

0.26

0.21

0.22

0.31

0.21

0.3

0.36

240

0.18

0.195

0.26

0.33

0.185

0.165

0.25

0.185

0.25

0.31

0.17

0.23

0.29

0.16

0.145

0.22

0.16

0.22

0.27

0.16

0.29

0.34

300

0.145

0.16

0.26

0.31

0.15

0.165

0.22

0.15

0.25

0.29

0.14

0.23

0.27

0.13

0.14

0.19

0.13

0.22

0.25

0.13

0.29

0.32

400

0.105

0.13

0.26

0.29

0.12

0.16

0.2

0.115

0.25

0.27

0.12

0.22

0.25

0.105

0.14

0.175

0.105

0.21

0.24

0.1

0.29

0.31

500

0.086

0.11

0.26

0.28

0.098

0.155

0.185

0.093

0.24

0.26

0.1

0.22

0.25

0.086

0.135

0.16

0.086

0.21

0.23

0.081

0.29

0.3

630

0.068

0.094

0.25

0.27

0.081

0.155

0.175

0.076

0.24

0.25

0.08

0.22

0.24

0.072

0.135

0.15

0.072

0.21

0.22

0.066

0.28

0.29

Note: *Spacings larger than one cable diameter will result in a large voltage drop.

r = conductor resistance at operating temperature

x = reactance

z = impedance