H07Z-U Power Lead for Container House
Cable Construction
Solid bare copper single wire to IEC 60228 Cl-1(H05Z-U / H07Z-U)
Bare copper strands to IEC 60228 Cl-2 (H07Z-R)
Cross-link polyolefin EI5 core insulation
Cores to VDE-0293 colors
LSOH – low smoke, zero halogen
Standard and Approval
CEI 20-19/9
CEI 20-35 (EN60332-1) / CEI 30-37 (EN50267)
CENELEC HD 22.9
EN50265-2-2
EN50265-2-1
CE Low Voltage Directive 73/23/EEC and 93/68/EEC
ROHS compliant
Features
Heat Resistance: Designed for high temperature environments to ensure safe and stable operation even at higher temperatures.
Low smoke and halogen free: Produces less smoke during combustion and is halogen free, which reduces the release of toxic gases during fire
and facilitates the safe evacuation of people.
Cross-linking technology: The cross-linking process is adopted to improve the mechanical properties and chemical resistance of the cable and prolong its service life.
Environmental protection: As it is halogen-free, it is friendly to the environment and reduces the release of harmful substances in case of fire.
Technical Characteristics
Working voltage:300/500v (H05Z-U)
450/750v (H07Z-U / H07Z-R)
Test voltage:2500 volts
Flexing bending radius:15 x O
Static bending radius:10 x O
Flexing temperature:+5o C to +90o C
Short circuit temperature:+250o C
Flame retardant:IEC 60332.1
Insulation resistance:10 MΩ x km
Application Scenario
Assembled buildings and energy-saving and environmentally friendly buildings: widely used for wiring inside modern buildings due to itsheat-resistant and environmentally friendly characteristics.
Containerized houses: for temporary or mobile buildings that need to be set up quickly and have high environmental requirements.
Internal wiring in distribution boards and switchboards: Used inside electrical equipment, such as switches and distribution facilities, to ensure the safety of power transmission.
Public facilities: Given its low-smoke, halogen-free characteristics, it is suitable for installation in public places such as government buildings to improve safety in the event of a fire.
In-pipe wiring: Commonly used for fixed wiring in pre-buried or pipelines to ensure stable and reliable connection of electrical equipment.
Due to its excellent performance and safety, H07Z-U power cord is widely used in electrical installations that require high heat resistance and low smoke and halogen free characteristics to ensure the safe and stable operation of electrical systems.
Cable Parameter
AWG |
No. of Cores x Nominal Cross Sectional Area |
Nominal Thickness of Insulation |
Nominal Overall Diameter |
Nominal Copper Weight |
Nominal Weight |
|
# x mm^2 |
mm |
mm |
kg/km |
kg/km |
H05Z-U |
|||||
20 |
1 x 0.5 |
0.6 |
2 |
4.8 |
8 |
18 |
1 x 0.75 |
0.6 |
2.2 |
7.2 |
12 |
17 |
1 x 1 |
0.6 |
2.3 |
9.6 |
14 |
H07Z-U |
|||||
16 |
1 x 1.5 |
0,7 |
2.8 |
14.4 |
20 |
14 |
1 x 2.5 |
0,8 |
3.3 |
24 |
30 |
12 |
1 x 4 |
0,8 |
3.8 |
38 |
45 |
10 |
1 x 6 |
0,8 |
4.3 |
58 |
65 |
8 |
1 x 10 |
1,0 |
5.5 |
96 |
105 |
H07Z-R |
|||||
16(7/24) |
1 x 1.5 |
0.7 |
3 |
14.4 |
21 |
14(7/22) |
1 x 2.5 |
0.8 |
3.6 |
24 |
33 |
12(7/20) |
1 x 4 |
0.8 |
4.1 |
39 |
49 |
10(7/18) |
1 x 6 |
0.8 |
4.7 |
58 |
71 |
8(7/16) |
1 x 10 |
1 |
6 |
96 |
114 |
6(7/14) |
1 x 16 |
1 |
6.8 |
154 |
172 |
4(7/12) |
1 x 25 |
1.2 |
8.4 |
240 |
265 |
2(7/10) |
1 x 35 |
1.2 |
9.3 |
336 |
360 |
1(19/13) |
1 x 50 |
1.4 |
10.9 |
480 |
487 |
2/0(19/11) |
1 x 70 |
1,4 |
12.6 |
672 |
683 |
3/0(19/10) |
1 x 95 |
1,6 |
14.7 |
912 |
946 |
4/0(37/12) |
1 x 120 |
1,6 |
16 |
1152 |
1174 |
300MCM(37/11) |
1 x 150 |
1,8 |
17.9 |
1440 |
1448 |
350MCM(37/10) |
1 x 185 |
2,0 |
20 |
1776 |
1820 |
500MCM(61/11) |
1 x 240 |
2,2 |
22.7 |
2304 |
2371 |