H05RN-F Power Cord for Stage Lighting Equipment
Cable Construction
Fine bare copper strands
Strands to VDE-0295 Class-5, IEC 60228 Class-5
Rubber core insulation EI4 to VDE-0282 Part-1
Color code VDE-0293-308
Green-yellow grounding, 3 conductors and above
Polychloroprene rubber (neoprene) jacket EM2
Model composition: H means that the cable is certified by a coordinating body, 05 means that it has a rated voltage of 300/500V, R means that the basic insulation is rubber, N means that the additional insulation is neoprene, and F means that it is of a flexible fine wire construction. The number 3 means that there are 3 cores, G means that there is grounding, and 0.75 means that the cross-section area of the wire is 0.75 square millimeters.
Applicable Voltage: Suitable for AC environment under 450/750V.
Conductor Material: Multi-strand bare copper or tinned copper wire to ensure good electrical conductivity and flexibility.
Technical Characteristics
Working voltage:300/500 volts
Test voltage:2000 volts
Flexing bending radius:7.5 x O
Fixed bending radius:4.0 x O
Temperature Range:-30o C to +60o C
Short circuit temperature:+200 o C
Flame retardant:IEC 60332.1
Insulation resistance:20 MΩ x km
Standard and Approval
CEI 20-19 p.4
CEI 20-35(EN 60332-1)
CE low voltage directive 73/23/EEC & 93/68/EEC.
IEC 60245-4
ROHS compliant
Features
Highly Flexible: designed with flexibility in mind for easy bending and placement in a wide range of environments.
Weather Resistant: Resistant to the effects of weather, including humidity, temperature changes, etc.
Oil and grease resistance: suitable for industrial environments where oil or grease is present.
Mechanical Stress Resistance: Has a certain degree of resistance to mechanical damage and is suitable for low to medium mechanical stress.
Temperature resistance: can withstand a wide range of temperatures, adapted to cold and high temperature environments.
Low smoke and non-halogen: In case of fire, less smoke and harmful gas emission, improving safety performance.
Application Scenario
Processing equipment: such as automation equipment and processing systems in factories.
Mobile Power: For power supply units that need to be moved, such as generator connections
Construction sites and stages: Temporary power supply, adapted to frequent movements and harsh conditions.
Audiovisual equipment: To connect sound and lighting equipment at events or performances.
Harbors and dams: these require durable and flexible cables.
Residential and temporary buildings: for temporary power supply, such as military barracks, plaster fixtures, etc.
Harsh industrial environments: in industrial environments with special requirements, such as drainage and sewage facilities.
Home and office: for electrical connections under low mechanical tension to ensure safety and reliability.
Due to its comprehensive performance, H05RN-F power cord is widely used in electrical connection situations where flexibility, durability and safety are required.
Cable Parameter
AWG |
No. of Cores x Nominal Cross Sectional Area |
Nominal Thickness of Insulation |
Nominal Thickness of Sheath |
Nominal Overall Diameter |
Nominal Copper Weight |
Nominal Weight |
# x mm^2 |
mm |
mm |
mm (min-max) |
kg/km |
kg/km |
|
18(24/32) |
2 x 0.75 |
0.6 |
0.8 |
5.7 – 7.4 |
14.4 |
80 |
18(24/32) |
3 x 0.75 |
0.6 |
0.9 |
6.2 – 8.1 |
21.6 |
95 |
18(24/32) |
4 x 0.75 |
0.6 |
0.9 |
6.8 – 8.8 |
30 |
105 |
17(32/32) |
2 x 1 |
0.6 |
0.9 |
6.1 – 8.0 |
19 |
95 |
17(32/32) |
3 x 1 |
0.6 |
0.9 |
6.5 – 8.5 |
29 |
115 |
17(32/32) |
4 x 1 |
0.6 |
0.9 |
7.1 – 9.2 |
38 |
142 |
16(30/30) |
3 x 1.5 |
0.8 |
1 |
8.6 – 11.0 |
29 |
105 |
16(30/30) |
4 x 1.5 |
0.8 |
1.1 |
9.5 – 12.2 |
39 |
129 |
16(30/30) |
5 x 1.5 |
0.8 |
1.1 |
10.5 – 13.5 |
48 |
153 |
H05RNH2-F |
||||||
16(30/30) |
2 x 1.5 |
0.6 |
0.8 |
5.25±0.15×13.50±0.30 |
14.4 |
80 |
14(50/30) |
2 x 2.5 |
0.6 |
0.9 |
5.25±0.15×13.50±0.30 |
21.6 |
95 |