62930 IEC 131 Red And Black Single-core Photovoltaic Cable
The sheath and insulation of 62930 IEC 131 are made of low-smoke halogen-free flame-retardant cross-linked irradiated polyolefin materials, which are flame-retardant and resistant to high temperature, cold and low temperature, ultraviolet rays and water degradation, which can effectively prevent fire hazards and ensure the safety of electricity use.
The use of high-precision tinned oxygen-free copper, stable conductivity, high oxidation resistance, small resistance, low conduction loss.
Photovoltaic cable is a special cable used in solar power generation system, mainly suitable for DC voltage end, lead connection of power generation equipment and bus connection between components, photovoltaic power generation equipment system with the highest voltage DC1.8KV.
62930 IEC 131 is a kind of TUV product certification cable, generally used in solar power plants or solar facilities, equipment wiring and connection, comprehensive performance, strong weather resistance, adapt to the use of various power station environments around the world, as a connection cable for solar energy devices, can be installed and used outdoors under different climatic conditions, can adapt to dry, humid indoor working environment.
Technical data:
Rated voltage | AC Uo/U=1000/1000VAC,1500VDC |
Voltage test on completed cable | AC 6.5kV, 15kV DC,5min |
Ambiengt temperature | (-40°C up to +90°C) |
Conductor maximum temperature | +120°C |
Service life | >25years (-40°C up to +90°C) |
The permitted short-circuit-temperature refer to a period of 5s is+200°C | 200°C, 5 seconds |
Bending radius |
≥4xϕ (D<8mm)) |
≥6xϕ (D≥8mm) | |
Compatibility test | IEC60811-401: 2012, 135±2/168h |
Acid and alkali resistance test | EN60811-2-1 |
Cold bending test | IEC60811-506 |
Damp heat teat | IEC60068-2-78 |
Sunlight resistance | IEC62930 |
O-zone resistance test of finished cable | IEC60811-403 |
Flame test | IEC60332-1-2 |
Smoke density | IEC61034-2, EN50268-2 |
Assessment of halogens for all non-metallic material | IEC62821-1 |
The Structure of Cable Refer to 62930 IEC 131:
Conductor Stranded OD.max(mm) | Cable OD.(mm) | Max Cond Resistance(Ω/km,20°C) | Current carring Capacity AT 60°C(A) |
1.58 | 4.90 | 13.7 | 30 |
2.02 | 5.40 | 8.21 | 41 |
2.50 | 6.00 | 5.09 | 55 |
3.17 | 6.50 | 3.39 | 70 |
4.56 | 8.00 | 1.95 | 98 |
5.6 | 9.60 | 1.24 | 132 |
6.95 | 11.40 | 0.769 | 176 |
8.74 | 13.20 | 0.565 | 218 |
Application Scenario:
Global Exhibitions:
Company Profile:
DANYANG WINPOWER WIRE&CABLE MFG CO., LTD. currently covers an area of 17000m2, has 40000m2 of modern production plants, 25 production lines, specializing in the production of high-quality new energy cables, energy storage cables, solar cable, EV cable, UL hookup wires, CCC wires, irradiation cross-linked wires, and various customized wires and wire harness processing.